Rachel GUI
From GOSIA
(→How to get the Rachel package: updated link to version 2.0.4.beta) |
(→Experiment planning and accuracy testing tools: Notes added on upgrades of simulation tools since the videos were recorded.) |
||
Line 94: | Line 94: | ||
===Experiment planning and accuracy testing tools=== | ===Experiment planning and accuracy testing tools=== | ||
+ | |||
+ | The simulation tools have been improved since the recording of these video tutorials. The user will find extra prompts for the details of the planned beam run, and estimated absolute measured counts will be calculated and displayed. The display format will look like the following: | ||
+ | |||
+ | <pre> | ||
+ | Experiment 1 Detector 1 | ||
+ | Raw Sim. Measured | ||
+ | Band Spin Band Spin Counts Error eps Counts Error | ||
+ | ------------------------------------------------------------------------------- | ||
+ | t 24.0 gsb 22.0 17 4 0.118 179 45 | ||
+ | t 24.0 t 22.0 18 4 0.151 121 29 | ||
+ | four 22.0 four 20.0 14 4 0.166 63 17 | ||
+ | </pre> | ||
+ | |||
+ | The "raw counts" are estimated from a typical efficiency curve for Gammasphere, and the estimated absolute efficiency <math>\epsilon</math> is given as "Sim. eps" for each transition. Possion counting errors are based on the raw counts, while additional error on the ''total'' (simulated) efficiency-corrected counts may be added by the user. | ||
# [http://www.pas.rochester.edu/~hayes/beta_rachel/accuracy_testing.html Testing the accuracy] of your Gosia calculations and the applicability of Gosia to a planned experiment. | # [http://www.pas.rochester.edu/~hayes/beta_rachel/accuracy_testing.html Testing the accuracy] of your Gosia calculations and the applicability of Gosia to a planned experiment. |