<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="https://www-user.pas.rochester.edu/~gosia/mediawiki/skins/common/feed.css?270"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://www-user.pas.rochester.edu/~gosia/mediawiki/index.php?action=history&amp;feed=atom&amp;title=Gosia_errors</id>
		<title>Gosia errors - Revision history</title>
		<link rel="self" type="application/atom+xml" href="https://www-user.pas.rochester.edu/~gosia/mediawiki/index.php?action=history&amp;feed=atom&amp;title=Gosia_errors"/>
		<link rel="alternate" type="text/html" href="https://www-user.pas.rochester.edu/~gosia/mediawiki/index.php?title=Gosia_errors&amp;action=history"/>
		<updated>2026-06-27T02:54:14Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.16.0</generator>

	<entry>
		<id>https://www-user.pas.rochester.edu/~gosia/mediawiki/index.php?title=Gosia_errors&amp;diff=795&amp;oldid=prev</id>
		<title>Hayes: Created page with &quot;The errors described below are reported in the output file, and/or in the terminal as a Gosia calculation terminates.  ==Exceeding the range of conversion coefficients==  When us...&quot;</title>
		<link rel="alternate" type="text/html" href="https://www-user.pas.rochester.edu/~gosia/mediawiki/index.php?title=Gosia_errors&amp;diff=795&amp;oldid=prev"/>
				<updated>2012-03-04T17:52:59Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot;The errors described below are reported in the output file, and/or in the terminal as a Gosia calculation terminates.  ==Exceeding the range of conversion coefficients==  When us...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;The errors described below are reported in the output file, and/or in the terminal as a Gosia calculation terminates.&lt;br /&gt;
&lt;br /&gt;
==Exceeding the range of conversion coefficients==&lt;br /&gt;
&lt;br /&gt;
When using the built-in internal conversion coefficient calculation function, there may be frequent reports similar to the following.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
Warning Egamma= 0.8596 exceeds range of conversion coefficients table for shell N7      &lt;br /&gt;
 0.8596       2.174E-03    5.586E-03    1.299E-02    1.212E-02    3.128E-02&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This does not necessarily indicate an accuracy error in Gosia calculations.  The internal conversion coefficients reported after the warnings can be checked for accuracy.  Accuracy errors in [[internal_conversion | internal conversion coefficients]] should only be large near K, L,... edges and for very low gamma-ray energies.  (reference needed)&lt;/div&gt;</summary>