Gosia errors
From GOSIA
for
Gosia errors
Jump to:
navigation
,
search
The errors described below are reported in the output file, and/or in the terminal as a Gosia calculation terminates. ==Exceeding the range of conversion coefficients== When using the built-in internal conversion coefficient calculation function, there may be frequent reports similar to the following. <pre> Warning Egamma= 0.8596 exceeds range of conversion coefficients table for shell N7 0.8596 2.174E-03 5.586E-03 1.299E-02 1.212E-02 3.128E-02 </pre> This does not necessarily indicate an accuracy error in Gosia calculations. The internal conversion coefficients reported after the warnings can be checked for accuracy. Accuracy errors in [[internal_conversion | internal conversion coefficients]] should only be large near K, L,... edges and for very low gamma-ray energies. (reference needed)