==Introduction== Any arbitrary overall normalization of the gamma-ray yield data is acceptable, unless the user is trying to normalize to the collision partner's gamma-ray yields or to the elastic cross section. This is because Gosia fits one overall normalization constant to all yield data, representing the factors of beam current, beam time, etc. ==Ge detector solid-angle corrections== If all of the Ge detectors span the same solid angle, then all of the data will be consistent if each count is efficiency-corrected by dividing by the relative efficiency <math>\epsilon (E_\gamma)</math> with an arbitrary overall normalization. However, if two data sets from different detector ''[[physical_germanium_type | types]]'' are included, then the following additional correction is necessary, since Gosia calculates (OP,INTI) yield per unit Ge solid angle and expects the same yield per unit solid angle in fitting (OP,MINI). Gosia expects to read "corrected" yields of <math>Y = N_{raw} / [\epsilon(E_\gamma) \Delta\Omega_{Ge}]</math>, where <math>Y</math> is the "corrected yield," <math>N_{raw}</math> is the measured count, <math>\epsilon(E_\gamma)</math> is the relative (or absolute) Ge detector efficiency and <math>\Delta\Omega_{Ge}</math> is the solid angle subtended by the germanium detector. Here, the solid angle is in units of sr (steradians). Obviously, if all Ge detectors span the same solid angle, then the <math>\Delta\Omega_{Ge}</math> term can be absorbed into the arbitrary overall normalization. However, if two or more of the Ge detectors subtend different solid angles, the <math>\Delta\Omega_{Ge}</math> term should be included. In cases where the overall normalization doesn't matter, the efficiency can absorb the solid angle and be taken on a scale of 0 < efficiency < 4pi, ''but the solid angle factor must not be included twice.'' ===Exceptions and warnings=== If the data sets are from detector clusters (see OP,RAW in the user manual), all of the Ge crystals in the cluster should be of the same physical type. This is because Gosia gives output and expects data from the user representing the count per unit solid angle ''of the crystal type,'' not of the total cluster solid angle. It is not clear how to handle summed Ge clusters of ''different physical types'' in Gosia. The OP,RAW command can be used to pass data to Gosia without an efficiency correction and/or for summed clusters. The solid angle divisors are still required, and for each cluster should be taken as <math>\Delta\Omega_{crystal}</math>—the solid angle of a single Ge detector in the cluster!
Return to
Normalization of yield data
.
Views
Page
Discussion
View source
History
Personal tools
Log in
Navigation
Main page
Community portal
Current events
Recent changes
Random page
Help
Search
Toolbox
What links here
Related changes
Special pages